Pressure Losses in Pipes
Product Code : JA-FMAHLE-10021
The pressure losses in pipes trainer (SKU JA-FMAHLE-10021) is a closed water circuit for investigating pressure losses in long pipe sections, bends, contractions, enlargements and valves. A submersible pump in a stainless steel tank feeds copper and steel test sections with up to eight pressure measuring points. It is supplied by JaincoLab for pipe flow practicals in engineering colleges, polytechnics and TVET institutes.
Specifications
The pressure losses in pipes trainer has a 110 litre stainless steel tank, a 0.45 kW pump giving up to 4.8 m³/h and 22.6 m head, three straight pipe sections of 2.5 m measuring length, a 20 litre volumetric tank and a rotameter.
| Product | Pressure Losses in Pipes |
| SKU | JA-FMAHLE-10021 |
| Water circuit | Closed, with 110 litre stainless steel tank and submersible pump |
| Pump | Power consumption 0.45 kW; max. flow rate 4.8 m³/h; max. head 22.6 m |
| Straight pipe sections | 3, measuring length 2.5 m, copper and steel of different diameters |
| Pipe diameters listed | Copper 18 x 1, 22 x 1 and 28 x 1 mm; steel ½ inch |
| Special sections | Pipe bends (copper 22 x 1 mm); contraction 18 x 1 mm and enlargement 28 x 1 mm; valves and fittings |
| Interchangeable fittings | Needle valve, shut-off valve, ball valve |
| Pressure measurement | Up to 8 measuring points with annular chambers; 8-tube manometer, Bourdon tube gauge, electronic differential pressure sensor |
| Flow measurement | Rotameter and 20 litre volumetric measuring tank |
Experiments on the pressure losses in pipes trainer
The pressure losses in pipes trainer lets students measure the pressure curve along long copper and steel pipes, find friction factors, and compare the losses caused by bends, sudden section changes and needle, shut-off and ball valves at different flow rates.
- Pressure curve along a measuring section with up to eight points
- Friction losses in copper and steel pipes of different diameters
- Losses in pipe bends and at sudden contraction and enlargement
- Opening characteristics of needle, shut-off and ball valves
- Flow measurement with rotameter and volumetric tank
Scope of supply
The listing covers the closed water circuit with stainless steel tank and pump, the straight and special pipe sections, the interchangeable valves, the 8-tube manometer, Bourdon gauge, electronic differential pressure sensor, rotameter and volumetric tank. Accessories, spares and quantities are confirmed on the quotation.
Packing, MOQ and lead time
MOQ, lead time and packing for the pressure losses in pipes trainer are confirmed on each quotation for the quantity and delivery destination. Single units and orders for complete fluid mechanics laboratories are supplied, with export to Africa, the Middle East and South and South-East Asia.
Frequently asked questions
How long are the test pipes?
The three straight pipe sections have a measuring length of 2.5 m and are made of copper and steel in different diameters.
Which valves can be compared?
A needle valve, a shut-off valve and a ball valve, fitted interchangeably in the valve section.
How is the flow rate measured?
With a rotameter and a 20 litre volumetric measuring tank; the pump gives up to 4.8 m³/h.
What should I send for a quotation?
Send the quantity and the delivery destination; MOQ, packing and lead time are confirmed on the quotation.
Related products
Other pipe flow units are listed in the JaincoLab fluid mechanics lab equipment range.
Request a quote
To order the pressure losses in pipes trainer, send the quantity and delivery destination through the JaincoLab contact page or email [email protected].