The SCR converters and reactive loads trainer is a power electronics board for studying SCR triggering in bridge converters that feed inductive and capacitive loads. It shows the limits of simple UJT triggering under reactive load and how an auxiliary SCR pulse-extender circuit overcomes them, then covers the half-controlled bridge with freewheeling diode and a fully controlled 4-SCR bridge. Resistive, inductive and capacitive loads can be used alone or together (SKU JA-PET-1418).
Specifications
Built-in parts and ratings listed:
| Product | SCR Converters and Reactive Loads |
| SKU | JA-PET-1418 |
| Trigger circuit | UJT relaxation oscillator and trigger pulse generator with resistance ramp control |
| Pulse transformers | Three, 1:1:1 |
| Mains transformer | 0-12 V at 100 mA, 0-12 V at 100 mA and 0-32 V at 500 mA |
| Auxiliary SCRs | Two, in pulse amplifier and extender configuration |
| Half-controlled bridge | Two SCRs and two diodes |
| Full bridge | Four SCRs |
| Loads | Resistive, inductive and capacitive, singly or combined |
| Mains | 230 V ±10%, 50 Hz AC; ON/OFF switch, fuse and jewel light |
| Patch cords | 4 mm stackable, 0.5 m |
| Weight | 3 kg approx. |
| Dimensions | W 340 x H 110 x D 210 mm |
| Also required | 3 3/4 digit multimeter; 20 MHz dual trace CRO (unearthed) |
Experiments on the converter trainer
The listed experiments are:
- SCR triggering in a half-controlled bridge under reactive load, and the limits of simple UJT triggering
- Triggering with an auxiliary SCR circuit using the extended pulse technique
- Half-controlled bridge operation and the action of the freewheeling diode
- Fully controlled 4-SCR bridge in converter mode
Scope of supply and ordering
The listing covers the converter trainer with its loads, patch cords and operating instructions, supplied by JaincoLab; the multimeter and oscilloscope are separate. Packing, lead time and the quantity per order are agreed on the quotation.
Frequently asked questions
Why does the trainer include auxiliary SCRs?
Simple UJT triggering is limited under reactive loads; the auxiliary SCRs extend the trigger pulse to fire the main SCRs.
Which loads can be connected?
Resistive, inductive and capacitive loads, individually or in combination.
Which bridge circuits are on the board?
A half-controlled bridge of two SCRs and two diodes, and a fully controlled bridge of four SCRs.
Related products
- Three Phase Half Controlled Thyristorized Bridge Converter
- SCR And AC Phase Control
- DV and DT Limitation Of SCRS
- Triac and AC Phase Control
More items of this type are listed in the power electronics trainers range.
Request a quote
Request a quotation for the SCR Converters and Reactive Loads (SKU JA-PET-1418) through the JaincoLab contact page. Buying under a laboratory tender? Use our tenders page.