Losses in Straight Pipes
Product Code : JA-FMAHLE-10001
The Losses in Straight Pipes apparatus (SKU JA-FMAHLE-10001), supplied by JaincoLab, measures the pressure drop along a straight pipe in an open system. A transparent elevated tank with an overflow keeps a constant static head on the pipe, and ball valves set the flow. This pipe friction apparatus shows the pressures at six measuring points on six tube manometers, all mounted on a clear panel on a sturdy, movable frame.
Specifications
The pipe loss apparatus is specified by an elevated tank of about 8 litres, a measuring section with 6 pressure points and 6 tube manometers reading -200 to 600 mm WC. Pipe diameter and length are not in the listing and are confirmed on the quotation.
| Product | Losses in Straight Pipes |
| SKU | JA-FMAHLE-10001 |
| Supply | Transparent elevated tank with overflow, approx. 8 L; constant static pressure |
| Flow control | Ball valves |
| Measuring section | 6 measuring points |
| Pressure display | 6 tube manometers |
| Pressure range | -200 to 600 mm WC |
| Mounting | Clear panel on a sturdy, movable frame |
| Pipe diameter and length | Confirmed on the quotation |
Experiments with the pipe friction apparatus
The apparatus is used to show how the pressure falls linearly along a straight pipe and how the head loss depends on the flow rate.
- Pressure losses in an open pipe system
- Pressure gradient along a straight pipe
- Head loss against flow rate
- Friction factor calculations for pipe flow
Scope of supply and ordering
The listing covers the Losses in Straight Pipes apparatus with elevated tank, pipe section, valves and 6 tube manometers on a movable frame. The water supply is provided by the user. Accessories, spares and quantities are confirmed on the quotation.
MOQ, lead time and packing are confirmed on each quotation for the quantity and the delivery destination. Single trainers and complete fluid mechanics laboratories for engineering colleges, polytechnics and TVET institutes, including tender orders, are supplied.
Frequently asked questions
How is a constant head kept?
A transparent elevated tank with an overflow feeds the pipe at constant static pressure.
How many pressure points are there?
Six, read on six tube manometers with a range of -200 to 600 mm WC.
What pipe size is used?
Pipe diameter and length are confirmed on the quotation.
Related products
See the complete fluid mechanics lab equipment range from JaincoLab for hydraulics, air flow and flow measurement.
Request a quote
For a quotation on the Losses in Straight Pipes apparatus, send the quantity, any accessories needed and the delivery destination through the JaincoLab contact page or email [email protected] with SKU JA-FMAHLE-10001. Tender and project enquiries can be sent through the tenders page.