Gas Chromatography
Product Code : JA-PLE-6447
The Gas Chromatography system (SKU JA-PLE-6447) is a modular gas chromatograph for routine quality-control and research analysis of volatile compounds in pharmaceutical, chemical and college laboratories. This gas chromatograph with dual injector can house three detectors at once and, with a dual-channel data station, run two of them simultaneously, choosing from FID, TCD, ECD, TID and PID detectors. It is supplied by JaincoLab.
Specifications
The standard outfit has a dual injector with room for a third, holds up to three detectors, and runs single-ramp temperature programming with an initial hold of up to 99 minutes and a programming rate from 0.1 to 30 °C; it can be set up for single or dual packed columns or single or dual capillary columns.
| Product | Gas Chromatography |
| SKU | JA-PLE-6447 |
| Injectors | Dual injector as standard; a third can be added |
| Detectors | Up to three installed; two operated at once with the dual-channel data station |
| Detector options | FID, TCD, ECD, TID, PID |
| Temperature programming | Single ramp; initial hold up to 99 min; programming rate 0.1 to 30 °C |
| Column configurations | Single or dual packed; single or dual capillary |
| All-glass configuration | Glass-lined injector, quartz jet FID and glass column |
| Optional attachments | Capillary inlet for split/splitless injection, carrier-gas mass flow controller, gas sampling valve, headspace attachment |
Applications of the gas chromatograph with dual injector
A gas chromatograph separates the volatile components of a sample in a heated column and measures each one at the detector, so this system handles routine assay and purity work, and in its all-glass configuration it can take heat-sensitive compounds such as alkaloids, steroids and volatile fatty acids.
- Routine quality-control analysis of volatile compounds in pharmaceutical and chemical laboratories
- Analysis of labile compounds such as alkaloids, steroids and volatile fatty acids with the all-glass configuration
- Gas and vapour samples through the optional gas sampling valve, and headspace work with the headspace attachment
- Instrumental analysis teaching in pharmaceutical analysis and chemistry laboratories
- Research work where injectors, detectors or a capillary attachment are added later
Scope of supply and ordering
The listing covers the gas chromatograph in the configuration agreed on the quotation: the number of injectors, the detectors chosen from FID, TCD, ECD, TID and PID, the packed or capillary column set-up and any optional capillary inlet, mass flow controller, gas sampling valve or headspace attachment. Accessories, spares and quantities are confirmed on the quotation.
Minimum order quantity, lead time and packing are confirmed on each quotation for the configuration and the delivery destination. JaincoLab supplies single systems to pharmaceutical analysis, testing and research laboratories and handles institutional and tender orders, including export to Africa, the Middle East and South and South-East Asia.
Frequently asked questions
Which detectors can be fitted?
FID, TCD, ECD, TID and PID detectors are offered; up to three can be installed and two operated at the same time with the dual-channel data station.
Can it run capillary columns?
Yes. It can be configured for a single or dual packed column or a single or dual capillary column, with an optional capillary inlet for split or splitless injection.
What temperature programming does it have?
Single-ramp programming with an initial hold time of up to 99 minutes and a programming rate from 0.1 to 30 °C.
Related products
- Advance Gas Chromatography
- Gas Chromatography With Electronic Pressure and Flow Control
- Columns for Gas Chromatography
- Gas Sampling Valve
Gas chromatographs and their accessories are listed with the JaincoLab pharmacy lab equipment range.
Request a quote
To order the Gas Chromatography system, send the configuration, your application and the delivery destination through the JaincoLab contact page or email [email protected]. Institutions and contractors buying under a tender can also reach us via the tenders page.