Auto Karl Fischer Titrimeter
Product Code : JA-MT-2208
The Auto Karl Fischer Titrimeter (SKU JA-MT-2208) carries out Karl Fischer titrations automatically to determine moisture content. It has a control unit and a separate titration unit: on START the KF reagent flows from the burette through a solenoid valve into the titration vessel, and the control unit stops the titration at the end point. This auto Karl Fischer titrimeter is supplied by JaincoLab.
Specifications
The set handles samples containing 1 to 50 mg of water, dispenses KF reagent from a pressure-filling auto-zero burette at 0.05 ml resolution, senses the end point by current through a dual platinum electrode and shows RUN, ADD and END on a 10-LED array.
| Product | Auto Karl Fischer Titrimeter |
| SKU | JA-MT-2208 |
| Sample size | 1 to 50 mg of water |
| KF dispensing resolution | 0.05 ml |
| Measuring electrode | Dual platinum |
| Detection | Current sensing, electronic control |
| Control unit display | Array of 10 LEDs; RUN, ADD and END indications in auto mode |
| Timer and alarm | Adjustable timer; buzzer |
| Control unit size and weight | 340 x 250 x 125 mm approx.; 2 kg approx. |
| Titration cell | Air-tight, 200 ml |
| Stirrer | Variable-speed magnetic stirrer with on/off control |
| KF flow | Automatic control valve (solenoid) for KF reagent |
| Burette | Pressure-filling auto-zero burette, 0.05 ml resolution |
| Power | 230 V ±10% AC, 50 Hz |
| Titration unit size and weight | 325 x 180 x 98 mm approx.; 3 kg approx. |
| Accessories listed | 10 ml clear glass burette, 500 ml reservoir bottle, moisture trap with rubber bellow, titration cell, dual platinum electrode, solenoid valve assembly, magnetic capsule, 2 clamps, rubber tubing, nozzle, instruction manual |
Applications of the auto Karl Fischer titrimeter
Automatic reagent addition and end point stop take the operator judgement out of routine KF titrations, which suits laboratories running many moisture determinations a day.
- Pharmaceutical and drug manufacturing quality control
- Food, sugar, wood, paper and textile moisture testing
- Petroleum refinery, chemical and fertiliser laboratories
- Pharmaceutical analysis practicals in pharmacy colleges
Scope of supply and ordering
The listing covers the control unit, titration unit and the accessories listed in the table. KF reagent is not part of the listing. Accessories, spares and quantities are confirmed on the quotation.
Minimum order quantity, lead time and packing are confirmed on each quotation for the number of sets and the delivery destination. JaincoLab supplies single sets and laboratory packages for pharmaceutical, college and testing laboratories.
Frequently asked questions
How is the titration controlled?
The control unit adds KF reagent through a solenoid valve and stops the titration automatically at the end point.
What sample size is it designed for?
Samples containing 1 to 50 mg of water.
What burette is used?
A pressure-filling auto-zero burette with 0.05 ml resolution; a 10 ml clear glass burette is listed.
Related products
- Microprocessor K.F. Moisture Titrator
- Microprocessor Potentiometer
- Digital Potentiometer
- Digital pH Meter
Karl Fischer instruments are grouped in the JaincoLab moisture titrator range.
Request a quote
To order the Auto Karl Fischer Titrimeter, send the quantity and delivery destination through the JaincoLab contact page or email [email protected], quoting SKU JA-MT-2208. For tender or project supply, see our tenders page.