Skin Fold Caliper
Product Code : JA-SFC-2408
The Skin Fold Caliper (SKU JA-SFC-2408) measures the thickness of a pinched fold of skin and the fat beneath it at standard body sites, the basis of body-fat estimation in anthropometry. This skinfold caliper reads 0 to 80 mm on a dial graduated in 0.20 mm and applies a jaw pressure of 10 g/mm² that stays constant across the range, keeping the measuring force the same whatever the fold thickness. It is supplied by JaincoLab for physiology, nutrition and sports science laboratories.
Specifications
The caliper measures from 0 to 80 mm with 0.20 mm dial graduation and 0.20 mm repeatability, at a measuring pressure of 10 g/mm² that stays constant over the range; the listed accuracy is 99.00%.
| Product | Skin Fold Caliper |
| SKU | JA-SFC-2408 |
| Measuring range | 0 to 80 mm |
| Dial graduation | 0.20 mm |
| Measuring pressure | 10 g/mm², constant over the range |
| Repeatability | 0.20 mm |
| Accuracy (as listed) | 99.00% |
Applications of the skinfold caliper
Measurements at sites such as the triceps, biceps, subscapular and suprailiac folds are combined in standard equations to estimate body fat.
- Body composition and body-fat estimation practicals in physiology and nutrition courses
- Anthropometry in sports science and physical education laboratories
- Growth and nutrition survey training in community health teaching
- Research projects that need repeatable skinfold measurements
Scope of supply and ordering
The listing covers the dial skinfold caliper. Any carrying case is confirmed on the quotation. Supply is subject to the buyer holding any licence or authorisation that applies to this item in the destination country. Accessories, spares and quantities are confirmed on the quotation.
Minimum order quantity, lead time and packing are confirmed on each quotation for the number of calipers and the delivery destination. Single units, class sets and bulk institutional and tender quantities are supplied.
Frequently asked questions
What is the measuring range?
0 to 80 mm, read on a dial graduated in 0.20 mm.
What jaw pressure does it apply?
10 g/mm², constant over the measuring range.
How repeatable are the readings?
The listed repeatability is 0.20 mm.
Related products
This model is listed in the JaincoLab skinfold calipers category.
Request a quote
To order the Skin Fold Caliper, send the quantity and delivery destination through the JaincoLab contact page or email [email protected], quoting SKU JA-SFC-2408. For tender or project supply, see our tenders page.