Digital Turbidity Meter
Product Code : JA-TM-2204
The Digital Turbidity Meter (SKU JA-TM-2204) measures the turbidity of suspensions in NTU for sewage and drinking water testing. A light source is focused on a test tube holding the sample, and the light scattered at right angles by the suspension is picked up by a photodiode and shown on a 3.5-digit LED display. This digital turbidity meter is supplied by JaincoLab in three range versions.
Specifications
The source lists three versions: 0-1000 NTU in four ranges at 0.01 NTU resolution, 0-1000 NTU in two ranges at 1 NTU resolution, both ±3% FS ±1 digit, and a nephelometer reading 0-200 NTU in two ranges at 0.01 NTU and ±2% FS ±1 digit.
| Product | Digital Turbidity Meter |
| SKU | JA-TM-2204 |
| Version A | 0-1000 NTU in 4 ranges (0-2, 20, 200, 1000 NTU); resolution 0.01 NTU; accuracy ±3% FS ±1 digit |
| Version B | 0-1000 NTU in 2 ranges (0-200, 1000 NTU); resolution 1 NTU; accuracy ±3% FS ±1 digit |
| Nephelometer version | 0-200 NTU in 2 ranges (0-20, 200 NTU); resolution 0.01 NTU; accuracy ±2% FS ±1 digit |
| Measuring principle | Light scattered at right angles to the beam |
| Display | 3.5-digit 7-segment LED |
| Light source | 6 V, 0.3 A tungsten lamp |
| Detector | Photodiode |
| Sample system | 30 mm clear glass test tubes |
| Power | 230 V ±10% AC, 50 Hz |
| Dimensions (L x B x H) | 245 x 260 x 125 mm approx. |
| Accessories listed | Set of 5 test tubes, operation manual, dust cover |
Applications of the digital turbidity meter
Turbidity in NTU is a routine figure for drinking water and effluent, and a right-angle scatter meter gives it directly from a filled test tube without calculation.
- Drinking water turbidity checks
- Sewage and effluent testing
- Water treatment plant process control
- Suspension and colloid studies in chemistry laboratories
- Environmental science practicals on water quality
Scope of supply and ordering
The listing covers the digital turbidity meter in the version chosen, with a set of 5 test tubes, operation manual and dust cover. Turbidity standards are confirmed on the quotation. Accessories, spares and quantities are confirmed on the quotation.
Minimum order quantity, lead time and packing are confirmed on each quotation for the version, number of meters and the delivery destination. JaincoLab supplies single meters and sets for water laboratories, colleges and tender orders.
Frequently asked questions
Which ranges are available?
0-1000 NTU in four ranges, 0-1000 NTU in two ranges, or a nephelometer version reading 0-200 NTU in two ranges.
How does the meter measure turbidity?
It detects the light scattered at right angles by the suspension in a 30 mm glass test tube, using a photodiode.
Are sample tubes included?
Yes. A set of 5 test tubes is listed with the meter.
Related products
Turbidity instruments are grouped in the JaincoLab turbidity meter range.
Request a quote
To order the Digital Turbidity Meter, send the version, quantity and delivery destination through the JaincoLab contact page or email [email protected], quoting SKU JA-TM-2204. For tender or project supply, see our tenders page.