Burette Acid
Product Code : JL-LEP-10253
The Burette Acid (SKU JL-LEP-10253) is used to hold and dispense acid as the titrant in acid-base titrations. This acid burette is Class A, 10 mL, in clear, bubble-free 3.3 borosilicate glass: a long graduated tube with a stopcock at the lower end and a tapered capillary outlet. The grease-free, interchangeable stopcock has a 1.5 mm bore, and the tolerance is ±0.02 to 0.03 mL, which suits careful volumetric work in school and college chemistry. JaincoLab supplies it as per DepEd guidelines.
Specifications
The burette is specified by class, glass, bore, lengths, capacity and stopcock: Class A, 3.3 borosilicate, 8 mm ID and 11 mm OD, a 300-457 mm scale within a 620-820 mm length, 10 mL, ±0.02-0.03 mL, and a grease-free 1.5 mm bore stopcock.
| Product | Burette Acid |
| SKU | JL-LEP-10253 |
| Type | Class A |
| Shape | Long graduated glass tube with stopcock at the lower end and tapered capillary outlet |
| Material | Clear, bubble-free 3.3 borosilicate glass |
| Inner diameter | 8 mm |
| Outer diameter | 11 mm |
| Scale length | 300 - 457 mm |
| Total length | 620 - 820 mm |
| Capacity | 10 mL |
| Tolerance | ± 0.02 - 0.03 mL |
| Stopcock | Grease-free, interchangeable, 1.5 mm bore |
| Specification reference | As per DepEd guidelines |
Applications of the acid burette
The burette is used in volumetric analysis where the volume of acid added must be read precisely. Typical uses are:
- Delivering acid titrant in acid-base titrations
- Finding the concentration of an alkali solution
- Standardising solutions in college practicals
- Teaching burette reading and end-point technique
Scope of supply and ordering
Each unit is one Class A acid burette with stopcock, as described in the specification table. Burette clamps, stands and flasks are separate items; accessories, spares and quantities are confirmed on the quotation.
Minimum order quantity, packing and lead time are confirmed on the quotation for the quantity and destination, with burettes packed for transit. JaincoLab supplies schools, colleges and analytical laboratories, and exports to Africa, the Middle East and South and South-East Asia.
Frequently asked questions
What class and capacity is the acid burette?
Class A, 10 mL.
What is the tolerance?
±0.02 to 0.03 mL.
What type of stopcock does it have?
A grease-free, interchangeable stopcock with a 1.5 mm bore.
Related products
Items used in titration:
Browse Laboratory Equipment Products or the JaincoLab chemistry lab equipment range.
Request a quote
To order the Burette Acid, send the quantity and delivery destination through the JaincoLab contact page or email [email protected]. Tender and project enquiries can be sent through the tenders page.